- SOLARWATT Manager flex
- Connect devices
- KEBA KeContact P30
KEBA KeContact P30
This page describes the connection of a ready installed KEBA KeContact P30 to the Manager flex.
Installation and configuration
Number of compatible wallboxes per SOLARWATT Manager flex: 1
Interface: LAN
Applicable documents
Requirements
- The charging pole is installed according to the KEBA installation instructions.
- The charging pole is connected to the local network via the Ethernet1 port X4 of the KEBA (LSA+ hard wiring).
Configuration for the manager
- Set the DSW1.3 dip switch to activate the UDP interface. This enables the communication with the manager flex.
- After setting the DSW1.3 dip switch, you must restart the KEBA charging pole (interruption of the power supply) so that the changes are effectively adopted.
Setup in SmartSetup
The Keba Wallbox is found and installed by the automatic device search, provided it is accessible in the local network.
The automatic device search and installation can take up to 5 minutes.
Correctly installed devices can be recognized by the message: Device is installed. in the device list. Furthermore, the list shows the current consumption data.