Alfen Eve Single

This page describes the connection of a ready installed Alfen Eve Single (Pro-line & S-line) to the Manager flex.

Installation and configuration

Number of compatible wallboxes per SOLARWATT Manager flex: 1

Interface: LAN

Requirements

Configuration with the Alfen ACE Service Installer

In order for the Manager flex to communicate with the Alfen wallbox, you must make the following settings in the Alfen ACE Service Installer:

  • In the Load Balancing menu, activate Active Load Balancing in the Active Balancing submenu
  • Select Energy Management System as data source
  • Activate Allow 1- and 3- phased charging (phase switching)
  • Select in the submenu Modbus TCP/IP EMS at Valdity Time (s): 60

Setup in SmartSetup

Search devices

  • Select drop-down menu in the charging station Alfen section.
  • In the configuration menu, enter the IP address of the Alfen wallbox under Hostname of the device and select Add device to search.
  • Click Search devices and install