Typical use cases are reading out the generation data of an incompatible inverter or reading out the consumption data of a heat pump.
Installation and configuration
When connecting the S0 meter to the Manager flex, the following PIN assignment must be observed:
EnergyMeter (3-phase) RLS (single directional meter)
The data of other devices can be read out with the help of the SOLARWATT EnergyMeter, for example:
- Generation data of an unsupported inverter
- Consumption data of a heat pump or another consumer
Proceed as follows to install the SOLARWATT EnergyMeter:
- Before connecting the meter to the Manager flex, check the wiring on the meter side.
- Establish and check that it is voltage-free.
- Connect the energy meter to the feed line of the inverter. Ensure the correct connection direction (current flow direction) at the energy meter.
- Connect the cable for S0 pulse transmission to the S0 connector (included in the scope of delivery).
- Connect the cable for S0 pulse transmission to the pulse output of the EnergyMeter.
- Connect the S0 plug to the S0 socket on the Energy Manager flex.
- Restore the voltage supply.